Printing Frequency#

Printing Frequency = <integer> [float]

Description / Usage#

This card sets the printing frequency, the step or time interval, at which Goma will print the solution variables to the Output EXODUS II file and the SOLN file. Definitions of the <integer> options, and the dependent [float] option when <integer> is set to 0, are:

<integer>

Specifies how often the solution will be printed.

> 0

Interval in time steps between successive printings of the solution, any positive integer value.

0

Controls printing of the solution at regularly spaced (uniform) intervals of time (every [float]), regardless of the number of time steps over that time interval

[float]

Elapsed time (in the same units as specified in the delta_t card) between successive printings of the solution (any positive number).

Examples#

Goma will print the solution every five time steps given the following sample card:

Printing Frequency = 5

Goma will print the solution every ten time units given the following sample card:

Printing Frequency = 0 10.