Level Set Freeze Interface Nodes#
Level Set Freeze Interface Nodes = {yes|no}
Description / Usage#
This card specifies whether the interface nodes of the level set are affected by the renormalization method. Permissible values for this option are:
- yes|on
The interface nodes are frozen during the renormalization process, meaning that their level set values are not changed.
- no|off
The interface nodes are not frozen, and their level set values may be changed during the renormalization process; this is the default.
Examples#
This is a sample card:
Level Set Freeze Interface Nodes = yes
Technical Discussion#
This option is useful to avoid unintended changes to the level set values at the interface nodes during the renormalization process.