Solidus Temperature#

Solidus Temperature = CONSTANT <float> [T]

Description / Usage#

This card is used to specify the model for the solidus temperature. Definitions of the input parameters are as follows:

CONSTANT

Name of the model for the solidus temperature.

  • <float> - the value of the solidus, Ts .

Examples#

The following is a sample card:

Solidus Temperature = CONSTANT 1.

Technical Discussion#

This card is required when using the ENTHALPY option on the Heat Capacity card.

References#

No References.