Maximum path step#
Maximum path step = <float>
Description/Usage
This card is required for all continuation problems. <float> is the absolute value of the maximum allowable increment in the continuation parameter between steps.
Examples
To allow the continuation parameter step size to increase but not allow a step size larger than 2, use:
Maximum path step = 2.0
Technical Discussion
For LOCA continuation problems, the function simple_step_control determines a step size for each step after the first. For continuation without LOCA, the function path_step_control performs this task. In either case, if a step size is computed which exceeds this limit, it is truncated to this value. For LOCA arc length continuation, an approximate limit is placed on the arc length step size.
Theory
No Theory.
FAQs
No FAQs.
References
No References.